On this page

RECORDING

Configure & record logs

Set up channels in SXTune, then verify recording on the Dash.

Configure logging from SXTune. Use the Dash to confirm readiness and manually start or stop a session.

Configure the logger in SXTune

  1. Connect in PC USB mode and confirm that SXTune identifies the Dash.
  2. Open the DeltaLog logger configuration. Choose the channels to record and a suitable sampling rate for each. Set the clock and session/file details.
  3. Select an existing logged channel as the automatic trigger and configure the required trigger settings. Keep the trigger channel in the logged list.
  4. Send the configuration to the logger. On SYSTEM, check the resulting channel count and date/time.
  5. Make a short stationary/bench recording with appropriate ECU data. Download it and verify channels, units and time before the main session.

Automatic recording

With automatic logging enabled, a valid configuration, usable SD card and ECU data, recording starts when the configured trigger condition is met. CONFIGURED means ready and waiting; look for LOGGING and increasing logged time to confirm that data is being written.

Make a short test recording to check that automatic logging starts and stops as intended.

Manually start and stop

  1. Check SD READY, the configured channel count and live ECU data on SYSTEM.
  2. Tap START LOGGER. This bypasses the automatic trigger; it does not bypass storage or configuration requirements.
  3. Confirm LOGGING and a rising logged time. If the button does not respond, tap its lower half and check the state again.
  4. Tap STOP LOGGER at the end and wait until recording has stopped before downloading, removing the card or switching off.
System page indicating LOGGING and the Stop Logger control
LOGGING and increasing logged time are the recording checks. Values shown are illustrative. Tap to enlarge.

Display channels and logged channels

Changing a Dash tile does not change the logger configuration. Broadcast channels can be displayed from received CAN data. The selector also offers static-table channels already configured for logging at a non-zero rate.

Displaying one of those static channels reuses the logger’s received sample; selecting it adds no separate CAN request stream. The logger’s existing polling may run while configured and waiting for the trigger. See static channel availability.

If a log does not start or stops early

Check SD readiness, configuration, ECU data and trigger behavior separately. Try a manual start to distinguish a trigger issue from a recording issue. Note the exact state if it shows a DTT/DTD file error or BUFFER OVERRUN. Then follow recording troubleshooting.

Screen reference