On this page
START HERE
Controls & System
Know the four main pages and the status checks to make before a session.
Tap a bottom tab, or swipe left or right, to move between SYSTEM, DASH, LAP and WIFI.
The last main page is remembered after restart. Editors have their own labelled save, cancel and navigation controls.
The four main pages
| Tab | What you can do |
|---|---|
| SYSTEM | Check logging, CAN, GPS, SD, clock and network status. Use START LOGGER / STOP LOGGER, SLEEP TIME and USB MODE. |
| DASH | View the RPM bar and six tiles. Tap a tile to select a channel; tap the tachometer to adjust its scale. |
| LAP | View distance to the start line, best/last/current lap and predictive delta. Change the circuit layout while stationary. |
| WIFI | Join a network, start the Dash access point, change device name/password or forget the saved network. |

Read the System status
| Area | Meaning / action |
|---|---|
| LOGGER | Check the state, configured channel count and logged time. Only LOGGING with increasing time confirms recording. CONFIGURED or STOPPED alone does not. |
| CAN | ACTIVE means recent frames have arrived. WAITING means no recent traffic. BUS OFF or ERROR needs investigation. The displayed baud rate must match the vehicle connection. |
| GPS | Connection, update rate, fix, satellites, speed and recognised track. Connection alone does not mean there is a valid fix. |
| SYSTEM | SD READY / ERROR / NO CARD, used/total space and USB role/status. |
| NETWORK | Wi-Fi connection/access-point state and current IP address. |
| Clock | Check the header before recording. If TIME NOT SET appears, or the value is wrong, set/check the logger clock from the connected PC software. |
| LAST RESET | An abnormal reset may show CRASH / PANIC, WATCHDOG or BROWNOUT / LOW VOLTAGE. Record the exact text if reporting a fault. |
Start and stop controls
START LOGGER requests a manual recording and bypasses the automatic trigger. STOP LOGGER closes the current recording. A valid logging configuration and working storage/ECU connection are still required.
If a START or STOP tap does not register, tap the lower half of the button and check that the logger state changes.
What is retained?
The main page, tile assignments, RPM settings, warning profiles, USB mode, sleep timeout and Wi-Fi settings are saved. USB role changes need a restart. Circuit layout selections are saved by venue. Treat predictive references as session data: confirm the layout and complete a valid lap whenever no reference is shown.