On this page

START HERE

Controls & System

Know the four main pages and the status checks to make before a session.

Tap a bottom tab, or swipe left or right, to move between SYSTEM, DASH, LAP and WIFI.

The last main page is remembered after restart. Editors have their own labelled save, cancel and navigation controls.

The four main pages

TabWhat you can do
SYSTEMCheck logging, CAN, GPS, SD, clock and network status. Use START LOGGER / STOP LOGGER, SLEEP TIME and USB MODE.
DASHView the RPM bar and six tiles. Tap a tile to select a channel; tap the tachometer to adjust its scale.
LAPView distance to the start line, best/last/current lap and predictive delta. Change the circuit layout while stationary.
WIFIJoin a network, start the Dash access point, change device name/password or forget the saved network.
System page with logger, CAN, GPS, SD and network cards
SYSTEM is the quickest place to check readiness. Example readings and time only. Tap to enlarge.

Read the System status

AreaMeaning / action
LOGGERCheck the state, configured channel count and logged time. Only LOGGING with increasing time confirms recording. CONFIGURED or STOPPED alone does not.
CANACTIVE means recent frames have arrived. WAITING means no recent traffic. BUS OFF or ERROR needs investigation. The displayed baud rate must match the vehicle connection.
GPSConnection, update rate, fix, satellites, speed and recognised track. Connection alone does not mean there is a valid fix.
SYSTEMSD READY / ERROR / NO CARD, used/total space and USB role/status.
NETWORKWi-Fi connection/access-point state and current IP address.
ClockCheck the header before recording. If TIME NOT SET appears, or the value is wrong, set/check the logger clock from the connected PC software.
LAST RESETAn abnormal reset may show CRASH / PANIC, WATCHDOG or BROWNOUT / LOW VOLTAGE. Record the exact text if reporting a fault.

Start and stop controls

START LOGGER requests a manual recording and bypasses the automatic trigger. STOP LOGGER closes the current recording. A valid logging configuration and working storage/ECU connection are still required.

If a START or STOP tap does not register, tap the lower half of the button and check that the logger state changes.

What is retained?

The main page, tile assignments, RPM settings, warning profiles, USB mode, sleep timeout and Wi-Fi settings are saved. USB role changes need a restart. Circuit layout selections are saved by venue. Treat predictive references as session data: confirm the layout and complete a valid lap whenever no reference is shown.

For screen-by-screen examples, see the screen reference.

Screen reference